Summary:
The Trouble with
Plugging With
trilingual summary
"Plugging" is the deceleration of a
polyphase motor by reversing applied voltage phase rotation at full
speed. Although this draws high line current, even exceeding that of
a normal start, plugging is the simplest and quickest braking method
(sometimes within less than one revolution).
Except for small motors, however,
manufacturers recommend against plug-stopping for two reasons.
First, it generates heat losses in both stator and rotor windings
that far exceed those during normal acceleration. Second, contactor
opening and out-of-phase reclosing causes severe torque and current
transients. The shaft torque may be several times the normal
breakdown value. Stator coils can undergo damaging stress.
Bringing the inertia of any machine to
full speed generates major heat loss in the driving motor. That heat
is a direct function of the square of the initial slip (1.0 for a
motor starting from rest) minus the square of the final slip
(usually a small fraction). For a phase reversal with the rotor
still turning at full forward speed, initial slip becomes 2.0, and
the final slip at standstill is 1.0. The difference in their squares
is 4.0 minus 1.0, or 3.0. Hence, motor heating loss for a plug stop
is three times that for an acceleration.
That ratio is not exact, for two
reasons. First, torque required by the load retards motor
acceleration, adding heat loss, whereas during plugging the load
torque aids during deceleration. Second, during deceleration the
system inertia tends to oppose the change in speed. Still, designers
normally consider one plug stop as the thermal equivalent of three
starts. Besides the thermal effect, plugging adds torsionbal shock
to couplings and other mechanical system components, and transient
torques may excite damaging mechanical resonance.
Finally, plugging cannot provide
holding torque to keep the motor at standstill. If power is not
removed slightly before zero rpm is reached, the motor will begin to
re-accelerate in the reverse direction. Special speed-sensing
controls may be needed to prevent that.
From
"The Trouble with Plugging " ...by
Richard L. Nailen, EA Engineering Editor -
published in Electrical Apparatus April 2004
© 2004
Barks Publications, Inc. All Rights Reserved.
|