Electrical Apparatus magazine, 
June 2003 When (and Why) is Motor Surface Temperature Important?

Although overheating of electrical machinery is most often considered only as a danger to winding insulation, temperatures of component surfaces (internal and external) are also a concern, for two reasons.

First, in an atmosphere containing combustible gas or dust, high motor surface temperature can cause a fire or explosion. If the motor is explosion-proof, of course, an internal gas explosion will be safely confined. However, many motors for petrochemical service are now of totally enclosed fan-cooled (TEFC) design. During either starting or full-speed running, then, rotor surfaces must remain below the ignition temperature of the atmosphere. 

Measuring rotor surface temperature is difficult. Thermocouples, temperature-sensitive paints, and slip comparisons each have disadvantages. Using those and other methods, the IEEE has published Standard 1349 as a guide to safe application of TEFC motors in Division 2 or Zone 2 locations.

In the United States, no specific standards govern external surface temperatures of motors. In Division 2 areas, the National Electrical Code Section 501.8(B) includes only a "Fine Print Note" saying "It is important to consider the temperature of internal and external surfaces that may be exposed to the flammable atmosphere." Although a valid warning, that offers no practical guidance to the motor user.

The second concern with motor surface temperature is its value as a diagnostic indicator of either winding or bearing overheating. Comparison of infrared thermography scans from time to time, and between individual motors, is a useful maintenance procedure. However, comparing single readings to some arbitrary temperature scale is unlikely to be productive. Such readings will be influenced by ambient temperature; by driven machine behavior; and by inaccuracies in the measurements themselves. That is particularly true for motor bearings. Frame surface temperature may also vary from end to end of the machine, with the frame size, and with the manufacturer. 

Despite their usefulness, then, surface temperatures of motor and generator components require careful, experienced interpretation

Industry news...

Featured Technical Article
June 2003

On this page is a summary of the Electrical Apparatus June 2003 featured technical article, by Richard L. Nailen, P.E. , "When (and Why)is Motor Surface Temperature   Important?" Wann (und warum) ist die Oberflächentemperatur eines Motors von Bedeutung? ... Quand (et pourquoi) la température de surface des moteurs est-elle importante? ... ¿Cuándo (y por que) es importante la temperatura de superficie de los motores?...

To order backissues which contain the foreign language summaries and the full article, call 312-321-9440 or visit our online webstore. See also links to additional technical summaries, below.

For our international readers, summaries of the technical articles are provided in German, French and Spanish. (Summaries do not appear when the article is U.S.-specific.)